Demo identity switcher. Authority is checked on the server for every decision, so switching roles here cannot approve a gate you do not hold.

TR-000004 Combustor liner thermal cycling to 2,000 cycles

RETURNED  ECTC-3 — Engine Component Test Cell 3 (critical hazard)

Review progress

  1. Safety Review Returned to requester
  2. Facility Readiness Review Not started
  3. Scheduling Confirmation Not started

Request detail

Principal investigator
D. Marchetti
Organisation code
MSD-7
Requested window
2027-04-05 to 2027-06-18
Summary
Accelerated thermal cycling of a ceramic matrix composite liner segment, with thermography each 250 cycles and post-test sectioning.
Hazard notes
Jet-A fuel handling, high-noise environment, exhaust gas scrubbing required.

Your action

No action available to you. This request is already returned and cannot be reviewed again.

The same check runs on the server when a decision is posted, so this is not merely a hidden button.

Gate decisions

Every decision ever taken on this request. Rows are append–only; nothing here is edited or deleted.
#GateDecision ReviewerRationaleRecorded
1 Safety Review RETURN r.lindqvist Exhaust scrubbing capacity is not addressed for the duration proposed. Please revise section 4 and resubmit. 2026-07-26 19:04

Audit trail

Sequence intact. 3 events, sequence 1–3, no gaps.

Append–only activity log. The sequence number is unique per request, so a removed row is detectable.
#EventActor DetailRecorded
1 CREATED D. Marchetti Request drafted for Combustor liner thermal cycling to 2,000 cycles. 2026-07-26 19:04
2 SUBMITTED D. Marchetti Entered Safety Review. 2026-07-26 19:04
3 GATE_RETURNED r.lindqvist Safety Review: RETURN. 2026-07-26 19:04

Machine-readable: JSON for TR-000004