TR-000004 Combustor liner thermal cycling to 2,000 cycles
RETURNED ECTC-3 — Engine Component Test Cell 3 (critical hazard)
Review progress
- Safety Review Returned to requester
- Facility Readiness Review Not started
- Scheduling Confirmation Not started
Request detail
- Principal investigator
- D. Marchetti
- Organisation code
- MSD-7
- Requested window
- 2027-04-05 to 2027-06-18
- Summary
- Accelerated thermal cycling of a ceramic matrix composite liner segment, with thermography each 250 cycles and post-test sectioning.
- Hazard notes
- Jet-A fuel handling, high-noise environment, exhaust gas scrubbing required.
Your action
No action available to you. This request is already returned and cannot be reviewed again.
The same check runs on the server when a decision is posted, so this is not merely a hidden button.
Gate decisions
| # | Gate | Decision | Reviewer | Rationale | Recorded |
|---|---|---|---|---|---|
| 1 | Safety Review | RETURN | r.lindqvist | Exhaust scrubbing capacity is not addressed for the duration proposed. Please revise section 4 and resubmit. | 2026-07-26 19:04 |
Audit trail
Sequence intact. 3 events, sequence 1–3, no gaps.
| # | Event | Actor | Detail | Recorded |
|---|---|---|---|---|
| 1 | CREATED | D. Marchetti | Request drafted for Combustor liner thermal cycling to 2,000 cycles. | 2026-07-26 19:04 |
| 2 | SUBMITTED | D. Marchetti | Entered Safety Review. | 2026-07-26 19:04 |
| 3 | GATE_RETURNED | r.lindqvist | Safety Review: RETURN. | 2026-07-26 19:04 |
Machine-readable: JSON for TR-000004